Jun 22, 2026Complaint
Pass2 items cited
- 47Food & non-food contact surfaces cleanable, properly designed, constructed & usedObserved cardboard used as shelving in walk-in cooler, freezer, and on bottom of prep tables. Instructed to remove and use shelving that is smooth and easily cleanable.
- 55Physical facilities installed, maintained & cleanObserved dust and food debris along walls behind 3-compartment sink and wall bases in dish area. Instructed to clean and maintain.
History
- Mar 17, 2026Short Form ComplaintPass
- Mar 3, 2026CanvassPass
2 items cited — show — hide
- 43In-use utensils: properly storedObserved serving utensils stored directly in cheese sauce and inside pan of greens in walk-in cooler. Instructed to remove from pan and store in a clean protective container or surface..
- 55Physical facilities installed, maintained & cleanObserved mop stored on the floor next to the utility sink. Instructed to provide and use a hanging device for proper storage and air drying. Must maintain.
- Sep 30, 2025Canvass Re-InspectionPass
3 items cited — show — hide
- 47Food & non-food contact surfaces cleanable, properly designed, constructed & usedObserved the inside of the deep fryer oil filtering unit with a build up of grease and food debris. Instructed to clean and maintain all
- 49Non-food/food contact surfaces cleanObserved accumulated grease and food debris on interior and exterior surfaces of cooking equipment, prep tables, coolers, freezers, shelving units. Instructed manager to clean and maintain.
- 55Physical facilities installed, maintained & cleanObserved a heavy accumulation of dirt, dust, grease, food splatter and food debris on the walls and floors especially along the hot food service line under and around the cooking equipment and non cooking equipment. Instructed to clean and maintain all areas.
- Sep 23, 2025CanvassFail
8 items cited — show — hide
- 16Food-contact surfaces: cleaned & sanitizedObserved excessive black and pink slimy substance build up on inside interior panel of ice machine and dripping onto ice for human consumption. Must remove build up, clean, and sanitize. Priority foundation 7-38-005
- 22Proper cold holding temperaturesObserved tcs foods held at improper internal temperatures in the prep area such as 20-30lbs of chicken ranging from 50-70f at time of inspection. Manager discarded and denatured a total 20-30lbs at $150. All cold tcs food must maintain 41f or below . Priority violation. Citation issued 7-38-005.
- 38Insects, rodents, & animals not presentObserved about 10-15 small flies located on the walls and ceilings in the rear food prep/dish washing area and 5-10 live roach throughout dish/ furnace area. Instructed to clean and sanitize affected areas and recommended contacting pest control for service. Priority foundation. Citation issued 7-38-020(a).
- 47Food & non-food contact surfaces cleanable, properly designed, constructed & usedObserved the inside of the deep fryer oil filtering unit with a build up of grease and food debris. Instructed to clean and maintain all
- 49Non-food/food contact surfaces cleanObserved accumulated grease and food debris on interior and exterior surfaces of cooking equipment, prep tables, coolers, freezers, shelving units. Instructed manager to clean and maintain.
- 55Physical facilities installed, maintained & cleanObserved a heavy accumulation of dirt, dust, grease, food splatter and food debris on the walls and floors especially along the hot food service line under and around the cooking equipment and non cooking equipment. Instructed to clean and maintain all areas.
- 57All food employees have food handler trainingObserved some food handler without certificates on site at time of inspection. Instructed all employees must complete food handler training and maintain records thereof on site at all times
- 58Allergen training as requiredObserved food service sanitation manager without food allergen training certificate. Instructed to meet requirement.
- Mar 19, 2024Canvass Re-InspectionPass
4 items cited — show — hide
- 10Adequate handwashing sinks properly supplied and accessible6-301.14: **C** Handwashing Signage FOUND HANDWASHING SINK IN THE FRONT PREPARATION AND DISHWASHING AREA WITHOUT SIGNAGE. MUST PROVIDE. INSTRUCTED THE PERSON IN CHARGE.
- 37Food properly labeled; original container3-302.12: **C** Food Storage Containers Identified with Common Name of Food FOUND FOOD STORAGE CONTAINER IDENTIFIED AS FLOUR WAS NOT LABELED. MUST LABEL. INFORMED THE PERSON IN CHARGE.
- 45Single-use/single-service articles: properly stored & used4-502.13: **C** Single-Service and Single-Use Articles- Use Limitations FOUND CARDBOARD USED TO LINE THE FLOOR AT THE FRYER AREA. MUST REMOVE. INSTRUCTED THE PERSON IN CHARGE NOT TO REUSE THE CARDBOARD. SURFACES MUST BE SMOOTH AND EASILY CLEANABLE.
- 55Physical facilities installed, maintained & clean6-201.11: **C** Floors, Walls, and Ceilings- Cleanability FLOORS BY THE DISH WASHING AREA NEED TO BE RE-GROUTED IN ORDER TO MAKE SAID SURFACE SMOOTH AND EASILY CLEANABLE. INSTRUCTED TO MAKE THE FLOOR SURFACE BY THE DISH WASHING AREA SMOOTH AND EASILY CLEANABLE.
- Mar 11, 2024CanvassFail
7 items cited — show — hide
- 2City of chicago food service sanitation certificateFound no city of chicago food service sanitation manager or valid certificate on site while time/temperature control for safety foods (chicken) are being prepared and served to the public. A valid city of chicago food service sanitation manager certificate must be on site at all times while tcs foods are prepared and served to the public. Priority foundation violation. 7-38-012. Citation issued.
- 10Adequate handwashing sinks properly supplied and accessibleFound handwashing sink in the front preparation and dishwashing area without signage. Must provide. Instructed the person in charge.
- 37Food properly labeled; original containerFound food storage container identified as flour was not labeled. Must label. Informed the person in charge.
- 38Insects, rodents, & animals not presentFound pest activity, approximately 50-70 small flies in area over and near the 3-compartment sink and mop sink areas. Instructed the person in charge to minimize small fly activity. Also found 5 dead roaches in the back area near the 3-compartment sink. Must clean and sanitize the affected areas. Suggested/recommended contacting pest control. Priority foundation. Citation issued 7-38-020(a).
- 45Single-use/single-service articles: properly stored & usedFound cardboard used to line the floor at the fryer area. Must remove. Instructed the person in charge not to reuse the cardboard. Surfaces must be smooth and easily cleanable.
- 55Physical facilities installed, maintained & cleanFloors by the dish washing area need to be re-grouted in order to make said surface smooth and easily cleanable. Instructed to make the floor surface by the dish washing area smooth and easily cleanable.
- 60Previous core violation correctedFound continued non- compliance from inspection report# 2578838 conducted on 7/20/23. The following previous core violations were not corrected: 5-205.15 observed a large waste water pipe directly in a floor drain without an air gap under the 3 compartment sink. Instructed to provide an adequate air gap (not less than 1 inch) in between the pipe and floor drain. Instructed to provide. Instructed manager to comply . Priority foundation violation. 7-42-090. Citation issued.
- Jul 31, 2023Canvass Re-InspectionPass
1 item cited — show — hide
- 51Plumbing installed; proper backflow devices5-205.15 observed a large waste water pipe directly in a floor drain without an air gap under the 3 compartment sink. Instructed to provide an adequate air gap (not less than 1 inch) in between the pipe and floor drain. Instructed to provide.
- Jul 20, 2023CanvassFail
10 items cited — show — hide
- 10Adequate handwashing sinks properly supplied and accessible6-301.14 observed no hand washing sign at the rear dish washing area hand washing sink. Instructed to provide.
- 16Food-contact surfaces: cleaned & sanitized4-501.114 observed facility inadequately sanitizing dishes at the 3 compartment sink. Observed the dish washer wash and rinse containers without sanitizing. Instructed to always set up the 3 compartment sink to wash rinse and sanitize all equipment and utensils at all times. Priority violation. Citation issued 7-38-025.
- 22Proper cold holding temperatures3-501.16(a:2,&b) observed inadequate cold holding temperature of tcs foods located in the food prep area; observed about 25 lbs of raw chicken at 67f and about 30 lbs of raw fish at 75f located in the food prep area. Instructed to always maintain all tcs foods at 41f or below at all times and discard and denature said tcs foods. Manager discarded said tcs foods during the inspection. Priority violation. Citation issued 7-38-005.
- 35Approved thawing methods used3-501.13 observed facility inadequately thawing raw fish in containers located next to the 3 compartment sink. Instructed to always properly thaw all tcs foods at all times by using refrigeration units or cold running water (not exceeding 70f) until product reaches 41f.
- 37Food properly labeled; original container3-601.11 observed some prepackaged desserts (cookies, banana pudding) for sale at the front customer counter without labels containing product business name, business address, ingredients, and if any allergens are present. Instructed to provide.
- 38Insects, rodents, & animals not present6-501.111 observed evidence of live small flies activity on site. Observed about 200 live small flies located on the walls and ceilings in the dish washing area and on boxes, walls, ceilings and flying around the food prep area and customer service counter. Instructed to eliminate live small flies actiivity, clean and sanitize affected areas and recommended contacting pest control for a service. Priority foundation. Citation issued 7-38-020(a).
- 45Single-use/single-service articles: properly stored & used4-502.13 observed cardboard being reused as a floor liner. Instructed to remove and do not reuse cardboard as floor liner. All surfaces must be smooth and easily cleanable.
- 49Non-food/food contact surfaces clean4-601.11(c) observed excessive accumulated food debris located inside of the fryers and on the door jams of the refrigeration units. Instructed to deep clean and sanitize all.
- 51Plumbing installed; proper backflow devices5-205.15 observed a large waste water pipe directly in a floor drain without an air gap under the 3 compartment sink. Instructed to provide an adequate air gap (not less than 1 inch) in between the pipe and floor drain. Instructed to provide.
- 55Physical facilities installed, maintained & clean6-501.12 observed accumulated dirt debris on the exterior of the garbage cans located at the front customer counter. Observed excessive food, grease and dirt debris on the floors throughout the food prep area. Instructed to clean and sanitize all.
- Aug 19, 2022Canvass Re-InspectionPass
3 items cited — show — hide
- 51Plumbing installed; proper backflow devicesObserved sink in toilet room to be slow draining. Water found on floor from sink instructed manager to repair sink.
- 53Toilet facilities: properly constructed, supplied, & cleaned5-501.17 observed no covered receptacle in toilet rooms. Instructed manager to provide covered receptacles in toilet rooms.
- 55Physical facilities installed, maintained & clean6-501.11 observed missing ceiling tiles in kitchen area; observed chipped wall paint in service area. Instructed manager to repair.
- Aug 9, 2022CanvassFail
6 items cited — show — hide
- 22Proper cold holding temperaturesObserved various tcs foods held at inadequate temperatures ranging from 45-57 f. Manager discarded 8 pounds of cheesecake, 2 pounds of coleslaw, 8 oz of banana pudding, & 3 pounds of ranch ($35). Priority violation 7-38-005. Citation issued
- 33Proper cooling methods used; adequate equipment for temperature controlObserved dessert cooler with an internal temperature of 46 f. Instructed manager to ensure all coolers have an internal air temperature of 41 f and below. Priority violation 7-38-005. Citation issued
- 38Insects, rodents, & animals not presentObserved over 50 small flies in dish area and throughout facility including in prep area, in customer dinning area, and in service line area. Instructed manager to service all affected areas. Pest control recommended. Priority foundation violation 7-38-020(a). Citation issued.
- 47Food & non-food contact surfaces cleanable, properly designed, constructed & usedObserved soiled can opener. Instructed manager to clean.
- 53Toilet facilities: properly constructed, supplied, & cleanedObserved no covered receptacle in toilet rooms. Instructed manager to provide covered receptacles in toilet rooms.
- 55Physical facilities installed, maintained & cleanObserved missing ceiling tiles in kitchen area; observed chipped wall paint in service area. Instructed manager to repair.
- Nov 18, 2021CanvassPass
5 items cited — show — hide
- 37Food properly labeled; original containerObserved no labels for bulk flour storage container located near the friers. Instructed person in charge all bulk and working food ingredient containers must be labeled with contents name.
- 39Contamination prevented during food preparation, storage & displayObserved boxes of food (fish, fries, and mozzarella sticks) stored on the floor in the walk-in freezer. Instructed manager to properly store and protect food items from contamination while stored by elevating at least 6 inches from the floor on raised shelving units.
- 47Food & non-food contact surfaces cleanable, properly designed, constructed & usedObserved the interior of the microwave in the kitchen soiled with food derbis and splash. Instructed to clean.
- 55Physical facilities installed, maintained & cleanObserved missing ceilings tile panels throughout the food prep and dish area. Instructed to replace missing panels. Observed a hole in the wall behind the ice machine, under the hand sink in the dish area, and along the walls in the rear. Instructed to seal.
- 56Adequate ventilation & lighting; designated areas usedObserved burnt out light bulb on the ceiling near the dish area. Instructed to replace light bulbs.
- Aug 18, 2020Complaint Re-InspectionPass
1 item cited — show — hide
- 55Physical facilities installed, maintained & cleanInstructed to clean floors and walls around and under equipment and sinks where needed and the floor in the storage area under shelves.
- Aug 11, 2020ComplaintFail
4 items cited — show — hide
- 10Adequate handwashing sinks properly supplied and accessibleAn exposed handsink is needed in the dishwashing area where the three comp sink is located for hand washing; must install with hot and cold running water, soap and handtowls. Priority foundation violation 7-38-030(c) issued.
- 55Physical facilities installed, maintained & cleanInstructed to clean floors and walls around and under equipment and sinks where needed and the floor in the storage area under shelves.
- 58Allergen training as requiredSee vio #60.
- 60Previous core violation correctedPrevious core violation not corrected from january 27, 2020 as required; must correct. #(58) instructed the person in charge that all city of chicago food service managers must obtain the required food allergen training. Priority foundation violation 7-42-090 issued.
- Jan 27, 2020CanvassPass w/ Conditions
5 items cited — show — hide
- 10Adequate handwashing sinks properly supplied and accessibleAn exposed handsink is needed in the dishwashing area where the three comp sink is located for hand washing; must install with hot and cold running water, soap and handtowls. Priority foundation violation 7-38-030(c).
- 37Food properly labeled; original containerObserved some bulk storage containers not labeled as required; must label containers with the name of the product inside of the container.
- 49Non-food/food contact surfaces cleanInstructed to clean bottom interior fryers to remove grease and shelves inside of refirgeration units.
- 55Physical facilities installed, maintained & cleanObserved unnecessary items in storage area; remove, organize and maintain to avoid clutter.
- 58Allergen training as requiredInstructed the person in charge that all city of chicago food service managers must obtain the required food allergen training.
- Feb 14, 2019ComplaintPass
3 items cited — show — hide
- 10Adequate handwashing sinks properly supplied and accessibleObserved no employees wash hands signage in restroom of facility utilized for employees. Informed person in charge to obtain and maintain signage.
- 55Physical facilities installed, maintained & cleanObserved facility with accumulation of unused and not maintained equipment with accumulation of food debris and in disrepair in rear of facility. Must remove unused nonfunctional equipment from premises not used for daily operations. Observed items and articles stored on floor in rear of facility . Must store items 6 inches from floor and maintain.
- 57All food employees have food handler training
- Sep 14, 2018Recent InspectionPass w/ Conditions
5 items cited — show — hide
- 3Management, food employee and conditional employee; knowledge, responsibilities and reporting2-102.14(a) observed no employee health policy on site. Instructed to provide an employee health policy that includes a signed acknowledgement from each employee. Priority foundation. No citation issued.
- 5Procedures for responding to vomiting and diarrheal events2-501.11 observed no written procedure on site for responding to vomiting and diarrheal events that can potentially occur inside of the food establishment. Instructed to provide. Priority foundation. No citation issued.
- 23Proper date marking and disposition3-501.17(b) observed ready to eat coleslaw out of the original packaging and held for over 24 hours without labels containing product name and date. Instructed to provide. Priority foundation. No citation issued.
- 36Thermometers provided & accurate4-204.112(b) observed no thermometer inside of the prep cooler unit located in the food prep area. Instructed to provide.
- 58Allergen training as requiredPa 100-0367 observed city of chicago food service sanitation manager without the required allergen training. Instructed to meet requirement and maintain.
- Sep 6, 2018Complaint Re-InspectionPass w/ Conditions
5 items cited — show — hide
- 3Management, food employee and conditional employee; knowledge, responsibilities and reporting2-102.14(a) observed no employee health policy on site. Instructed to provide an employee health policy that includes a signed acknowledgement from each employee. Priority foundation. No citation issued.
- 5Procedures for responding to vomiting and diarrheal events2-501.11 observed no written procedure on site for responding to vomiting and diarrheal events that can potentially occur inside of the food establishment. Instructed to provide. Priority foundation. No citation issued.
- 23Proper date marking and disposition3-501.17(b) observed ready to eat coleslaw out of the original packaging and held for over 24 hours without labels containing product name and date. Instructed to provide. Priority foundation. No citation issued.
- 36Thermometers provided & accurate4-204.112(b) observed no thermometer inside of the prep cooler unit located in the food prep area. Instructed to provide.
- 58Allergen training as requiredPa 100-0367 observed city of chicago food service sanitation manager without the required allergen training. Instructed to meet requirement and maintain.
- Aug 30, 2018ComplaintFail
10 items cited — show — hide
- 3Management, food employee and conditional employee; knowledge, responsibilities and reporting2-102.14(a) observed no employee health policy on site. Instructed to provide an employee health policy that includes a signed acknowledgement from each employee. Priority foundation. No citation issued.
- 5Procedures for responding to vomiting and diarrheal events2-501.11 observed no written procedure on site for responding to vomiting and diarrheal events that can potentially occur inside of the food establishment. Instructed to provide. Priority foundation. No citation issued.
- 22Proper cold holding temperatures3-501.16 (a)(2) observed ready to eat time/temperature control for safety foods, coleslaw (30 small containers), at the improper cold holding temperature of 60.1f. Instructed to always maintain all time/temperature control for safety foods at 41f or below at all times. Manager discarded 30 containers of coleslaw worth $10. Priority violation. Citation issued 7-38-005.
- 23Proper date marking and disposition3-501.17(b) observed ready to eat coleslaw out of the original packaging and held for over 24 hours without labels containing product name and date. Instructed to provide. Priority foundation. No citation issued.
- 28Toxic substances properly identified, stored, & usedObserved a container of a toxic substance in a spray bottle not labeled with the common name of the substance, employee states substance is use the clean the customer dining tables. Instructed to clearly label all toxic substance cleaners taken from bulk supplies and maintain. Priority foundation. Citation issued 7-38-005.
- 36Thermometers provided & accurate4-204.112(b) observed no thermometer inside of the prep cooler unit located in the food prep area. Instructed to provide.
- 38Insects, rodents, & animals not present6-501.111 observed about 40 small flies located on the walls and ceilings in the rear food prep/dish washing area and 1 live roach inside of a box in the dry storage area. Instructed to clean and sanitize affected areas and recommended contacting pest control for service. Priority foundation. Citation issued 7-38-020(a).
- 39Contamination prevented during food preparation, storage & display3-301.11 observed a water bottle stored directly inside of ice that is for human consumption located inside of the ice machine. Instructed to never store any items inside of the ice machine that is use for human consumption and instructed to remove water bottle and discard the ice. Manager corrected during the inspection. Priority violation. Citation issued 7-38-005.
- 55Physical facilities installed, maintained & clean6-501.12 observed floors in the rear dry storage area with accumulated dirt and dust debris. Instructed to clean and maintain. 6-201.16(a) observed missing ceiling tiles thruout the food prep area. Instructed to replace and maintain. 6-501.114observed items stored on the floor and unnecessary clutter (old floor mats and old equipment) being stored in the rear dry storage and rear dish washing area. Instructed to elevate all items at least 6 inches from the ground and remove unnecessary clutter and maintain.
- 58Allergen training as requiredPa 100-0367 observed city of chicago food service sanitation manager without the required allergen training. Instructed to meet requirement and maintain.
- Apr 26, 2018Complaint Re-InspectionPass
5 items cited — show — hide
- 30Food in original container, properly labeled: customer advisory posted as neededObserved dry storage (seasonings) containers not labeled. Instructed to label and maintain.
- 31Clean multi-use utensils and single service articles properly stored: no reuse of single service articlesObserved scoops being stored directly in dry storage containers and utensils improperly stored stored between the wall and the middle exposed hand sink. Instructed to properly store utensils and maintain.
- 32Food and non-food contact surfaces properly designed, constructed and maintainedObserved a stained cutting board with deep dark grooves. Instructed to replace and maintain.
- 34Floors: constructed per code, cleaned, good repair, coving installed, dust-less cleaning methods usedObserved floors around the grease trap with accumulated food and dirt debris. Instructed to clean and maintain.
- 38Ventilation: rooms and equipment vented as required: plumbing: installed and maintainedObserved cold water knob stripped on the rear exposed hand sink. Observed no air gap at least 6 inches under the 2 compartment sink and rear exposed hand sink. Instructed to repair cold water knob and provide a 6 inch air gap under said sinks and maintain.
- Apr 19, 2018ComplaintFail
6 items cited — show — hide
- 19Outside garbage waste grease and storage area; clean, rodent proof, all containers coveredObserved outside grease dumpster lid not maintained with accumulated grease on the grease dumpster lid. Instructed to clean and maintain. Serious violation 7-38-020.
- 30Food in original container, properly labeled: customer advisory posted as neededObserved dry storage (seasonings) containers not labeled. Instructed to label and maintain.
- 31Clean multi-use utensils and single service articles properly stored: no reuse of single service articlesObserved scoops being stored directly in dry storage containers and utensils improperly stored stored between the wall and the middle exposed hand sink. Instructed to properly store utensils and maintain.
- 32Food and non-food contact surfaces properly designed, constructed and maintainedObserved a stained cutting board with deep dark grooves. Instructed to replace and maintain.
- 34Floors: constructed per code, cleaned, good repair, coving installed, dust-less cleaning methods usedObserved floors around the grease trap with accumulated food and dirt debris. Instructed to clean and maintain.
- 38Ventilation: rooms and equipment vented as required: plumbing: installed and maintainedObserved cold water knob stripped on the rear exposed hand sink. Observed no air gap at least 6 inches under the 2 compartment sink and rear exposed hand sink. Instructed to repair cold water knob and provide a 6 inch air gap under said sinks and maintain.
- Oct 30, 2017Complaint Re-InspectionPass
1 item cited — show — hide
- 32Food and non-food contact surfaces properly designed, constructed and maintainedObserved excessive rust on wall of walk in cooler. Must remove or paint. Must maintain same.
- Oct 20, 2017ComplaintFail
6 items cited — show — hide
- 11Adequate number, convenient, accessible, designed, and maintainedObserved hot water turned off at pipe below hand sink in kitchen. Instructed must have hot and cold water (soap and paper towels) available at hand sinks at all times. Operator turned on hot water at pipe during inspection. Hot water is not available. Critical violation 7-38-030.
- 18No evidence of rodent or insect outer openings protected/rodent proofed, a written log shall be maintained available to the inspectorsObserved approximately 25 small, black flies in rear prep area (in rear room, back right side, where 2 compartment sink is). Instructed to clean and sanitize area, and to eliminate pest issue. Serious violation 7-38-020.
- 32Food and non-food contact surfaces properly designed, constructed and maintainedObserved excessive rust on wall of walk in cooler. Must remove or paint. Must maintain same. Observe cardboard used as a liner in areas of kitchen. Must remove all cardboard. All surfaces must be non-porous, smooth and easily cleanable. Must maintain same.
- 33Food and non-food contact equipment utensils clean, free of abrasive detergentsObserved soiled containers, and excessive dust/dirt build up on shelves in rear prep area, on the right side. Must detail clean and sanitize items. Must maintain same.
- 38Ventilation: rooms and equipment vented as required: plumbing: installed and maintainedObserved leak at pipes under hand sink in kitchen area. Must repair and maintain same. Observed drain line laying inside hand sink in kitchen area. Must remove. No items may be in hand sink.
- 41Premises maintained free of litter, unnecessary articles, cleaning equipment properly storedObserved mop stored inside mop bucket in rear prep area. Mops must be hung to dry, or be properly stored off the floor and out of buckets to dry. Must maintain same.
- Apr 18, 2017CanvassPass
6 items cited — show — hide
- 30Food in original container, properly labeled: customer advisory posted as neededThe bulk ingredient containers are not label. Instructed to label. Maintain same.
- 32Food and non-food contact surfaces properly designed, constructed and maintainedThe reach in white chest freezer has thick ice build up. Instructed to remove and maintain.
- 33Food and non-food contact equipment utensils clean, free of abrasive detergentsThe storage racks inside the walk in cooler and in the food preparation area has food and dirt build up. Instructed to clean and maintain.
- 34Floors: constructed per code, cleaned, good repair, coving installed, dust-less cleaning methods usedThe floors inside the walk in cooler and under/around the cooking equipment has food, grease and dirt build up. Instructed to clean and maintain.
- 35Walls, ceilings, attached equipment constructed per code: good repair, surfaces clean and dust-less cleaning methodsThe walls in the front food preparation has food spills and dirt on them. Instructed to clean and maintain. The ceiling tiles in the rear are missing, must provide. Also, must replace the water stained ceiling tiles in the front/rear food preparation and dining area.
- 36Lighting: required minimum foot-candles of light provided, fixtures shieldedThe lighting in the walk in cooler is poor. Instructed to provide adequate lighting and maintain.
- Sep 9, 2016Short Form ComplaintPass
- Aug 4, 2016CanvassPass w/ Conditions
3 items cited — show — hide
- 21* certified food manager on site when potentially hazardous foods are prepared and servedNo certified food and santation manager on site while handling and serving potentially hazardous foods, instructed to ontain serious citation issued 7-38-012
- 38Ventilation: rooms and equipment vented as required: plumbing: installed and maintainedLeaky pipe under the hand sink at front prep area, instructed to repair.
- 41Premises maintained free of litter, unnecessary articles, cleaning equipment properly stored3-comp sink not clean, old fixture on the side of drain board. Instructed to clean and maintain.
- Jan 27, 2016LicensePass
2 items cited — show — hide
- 36Lighting: required minimum foot-candles of light provided, fixtures shieldedMissing light shield at walk-in coolr and freezer. Instructed to install.
- 38Ventilation: rooms and equipment vented as required: plumbing: installed and maintainedNo backflow preventtion device at ice machine. Instructed to install.