Wicker64 Bar And Grill
1745 W North Ave, Chicago, IL
Oct 21, 2026Canvass Re-Inspection
PassHistory
- Oct 19, 2026CanvassFail
2 items cited — show — hide
- 51Plumbing installed; proper backflow devicesObserved dish machine is connected directly to grease trap in basement. Direct connection may not exist. Must repair. Priority violation. 7-38-030(c).
- 52Sewage & waste water properly disposedObserved sewage backup at grease trap when water is running at 3-compartment sink in basement. Must correct plumbing issue. Priority violation. 7-38-030(c). Citation issued.
- Sep 26, 2025License Re-InspectionPass
2 items cited — show — hide
- 51Plumbing installed; proper backflow devices5-204.12 : observed no back flow device on ice machine to be seen for servicing.
- 55Physical facilities installed, maintained & clean6-201.13 : must seal gaps underneath counter tops in 1st fl. Prep area.
- Sep 23, 2025LicenseFail
11 items cited — show — hide
- 3Management, food employee and conditional employee; knowledge, responsibilities and reportingObserved no signed employees health policies must provide and maintain.(priority foundation 7-38-010)
- 16Food-contact surfaces: cleaned & sanitizedObserved excessive pink build up on interior panel of ice machine and dripping onto ice.must remove ice clean and sanitize.(priority foundation 7-38-005)
- 39Contamination prevented during food preparation, storage & displayMust provide a splash guard on both sides of mopsink next to dish storage racks and 3- compartment sink.
- 44Utensils, equipment & linens: properly stored, dried, & handledMust invert multi-use utensils on dish storage shelves in basement.
- 47Food & non-food contact surfaces cleanable, properly designed, constructed & usedMust remove rust from lower shelving units of prep tables in basement.
- 49Non-food/food contact surfaces cleanMust clean debris build up from chest freezer,wall potato peeler.
- 51Plumbing installed; proper backflow devicesObserved no back flow device on ice machine to be seen for servicing.
- 52Sewage & waste water properly disposedObserved grease trap overflowing and pooling water onto floor when water is released from basement 3- compartment sink must repair and maintain.(priority 7-38-030(c)
- 55Physical facilities installed, maintained & cleanMust seal gaps underneath counter tops in 1st fl. Prep area,gaps along wall bases in bar area,holes in walls at stainless steele wall panels at cooking equipment.
- 56Adequate ventilation & lighting; designated areas usedMust replace burntout lights in basement prep/dish washing area.
- 58Allergen training as requiredObserved no food allergen training for food manager must provide and maintain.
Source: Chicago Department of Public Health (this place's raw rows). Results are shown exactly as the department published them; each city grades its own way. Something wrong? info@oxinion.com